產(chǎn)品描述
µ-Gard 氣體變送器用于連續(xù)檢測(cè)環(huán)境中的各種氣體,廣泛應(yīng)用于各種環(huán)境,性能可靠,連接方便
應(yīng)用
可適合各種商業(yè)應(yīng)用,基于標(biāo)準(zhǔn)的4–20 mA 或 2-10 V模擬量輸出,µ-Gard可配合各種控制器使用
特點(diǎn)
·連續(xù)檢測(cè) ·便于維護(hù)和校正
·內(nèi)置電源保護(hù)電路 ·過(guò)載和短路保護(hù)
·長(zhǎng)壽命傳感器 ·低零點(diǎn)漂移
·有效防止中毒 ·4 – 20 mA 標(biāo)準(zhǔn)輸出
·可選2 - 10 V 輸出
技術(shù)參數(shù)
|
MA-0
CO
|
MA-9
O2
|
MA-9
NO
|
MA-2
NO2
|
MA-5
SO2
|
MA-2
NH3
|
MA-2
Ex
|
MA-2
NH3
|
MA-3
NH3
|
MA-4
Freon
|
MA-4
Ex
|
MA-3
ETO
|
傳感器原理
|
電化學(xué),擴(kuò)散式
|
催化燃燒式
|
半導(dǎo)體
|
響應(yīng)時(shí)間 t90 (s)
|
≤ 50
|
≤ 15
|
≤ 45
|
≤ 25
|
≤ 15
|
≤ 120
|
≤ 10 (甲烷)
|
≤ 100
|
≤ 50
|
≤ 30
|
≤ 50
|
分辨率
|
±3ppm
|
±0.1vol. %
|
±0.2 ppm
|
±0.2 ppm
|
0.2 ppm
|
<±20 ppm
|
± 1% of reading
|
---
|
---
|
---
|
---
|
重復(fù)性 (%)
|
± 3 %
|
---
|
---
|
± 2 %
|
± 2 %
|
---
|
---
|
---
|
---
|
---
|
---
|
零點(diǎn)漂移/年
|
< 5%
|
---
|
<0.3 ppm
|
<0.2 ppm
|
<0.2 ppm
|
---
|
±<6%LEL (Methane)
|
---
|
---
|
---
|
---
|
靈敏度漂移/月
|
---
|
< 4%/12
|
< 5%/12
|
< 2%/1
|
< 2%/1
|
< 2%/1
|
± < 1.5% Methane
|
---
|
---
|
---
|
---
|
傳感器壽命 (正常使用環(huán)境)年
|
|
≥ 2
|
≥ 2
|
≥ 2
|
≥ 2
|
≥ 2
|
≥ 3
|
≥ 5
|
最長(zhǎng)存貯時(shí)間
|
6 months
|
12 months
|
操作環(huán)境
|
濕度(無(wú)冷凝)
|
15 – 90 % RH
|
15 – 90 % RH
|
15 – 95 % RH
|
溫度
|
工作溫度
|
-10 to + 50°C
|
-30 to
+ 50 °C
|
-15 to + 50°C
|
-15 to + 50 °C
|
存貯溫度
|
5 C to + 40 °C
|
0 to + 50 °C
|
0 to + 50 °C
|
工作壓力
|
1大氣壓±10%
|
規(guī)格參數(shù)
供電 18 - 28 VDC
耗電量 電化學(xué)傳感器: 22 mA, 0,6 VA
催化/半導(dǎo)體傳感器: 35 mA, max. 0.85 VA
外殼(F) GW 塑料 75 GWT
阻燃性 UL 94: V0
外殼顏色 RAL 7032 (淺灰)
尺寸(d x H) 87 x 45,5 mm
重量 約 0.2 kg
防護(hù)等級(jí) IP 43
安裝方式 壁掛式
線纜 標(biāo)準(zhǔn)3線
線纜連接 0.25 mm2 (24 AWG)- 2.5 mm2 (14 AWG)
最大環(huán)路負(fù)載電阻500 Ω
輸出信號(hào)
模擬輸出信號(hào)
標(biāo)準(zhǔn) 4-20 mA 4 – 20 mA, ≤ 500 Ω帶過(guò)載和短路保護(hù)
可選 2-10 V 2 – 10 V, ≥ 50 kΩ帶過(guò)載和短路保護(hù)
執(zhí)行標(biāo)準(zhǔn) EMC 2004/108/EEC, CE
質(zhì)保期 12個(gè)月(不含傳感器)